Add to Cart
Operation
①Turn on the generator, the digital display "HH", the controller and cooling fan of X ray generator
startup, X ray warning light on, then the buzzer sounds. After 15 seconds, the digital display time knob set value, the buzzer stop, standby light on.
②Adjust the knob to select the required exposure time.
③Before the operation we should warm-up the machine, in order to improve the ray tube vacuum
degree, if the vacuum degree is bad, it will burn or breakdown the X-ray tube, leading to failure, and even discarded
Standard Configuration
NO. | Name | QTY | Remarks |
1 | X ray flaw detector | 1 | |
2 | controller | 1 | |
3 | Connection cable(10 cores) | 1 | |
4 | Power cable(2 cores) | 1 | |
5 | Ground lead | 1 | |
6 | Fuse(3A) | 5 | |
7 | Attached files | 1 |
Working Conditions
Environment temperature: -25℃-40℃
Relative humidity: no bigger than 85%
Safe work pressure: 0.35-0.50mPa
Note, Do not use when the pressure is under 0.35mPa
Generator Appearance
1 Gas pressure gauge 2 Cable line socket
3 Caution light 4 X ray generate area
5 Cooler fan
Controller Appearance
1 Fault code and exposure chart 2 Standby light
3 HV light 4 Digital display
5 Time knob 6 KV presetting knob
7 “HV on” key 8 “HV off” key
9 Power switch 10 Connection cable socket
11 Power cable socket 12 Earthing wire
13 Fuse holder(3A)
The main parts in the controller are:KV control panel, mA control panel, microcomputer control panel, protection board, Controllable silicon high voltage module, LC filter, main,assistant silicon control inverter system. The inner controller has cooling fans, vent-windows on the side and back.