Mitech Intelligent Ultrasonic Flaw Detector MFD620C with extensive data storage
Product Overview
Based on ultrasonic pulse reflection testing principle, MFD620C controls all testing process by the mini-processor. And it has low power design. It can work continuously more than 8 hours.With large capacity, digital multi-color TFT LCD, light weight, stable performance and favorable price, MFD620C is one of our company’s high promoted super cost performance and economically ultrasonic flaw detector.
Main Body
1 Belt 2 Swiveling support 3 LOGO pad 4 LCD Display 5 Menu Keys
6 Alarm LED 7 Power LED 8 Keypad 9 Rotary Knob 10 Product Label
11 Battery Case Cover 12 Power adapter port 13 USB Socket
14 Probe Cable Port (Transmit) 15 Probe Cable Port(Receive)
Operating Method
Simple Operation Way:
1. Connect the probe to instrument with probe cable
2. Power on the instrument
3. Choose the channel and clear the present channel
4. Calibration the probe
Straight Probe: P-Delay
Angle Probe: P-Delay, X-value, Angle
5. Make AVG curve (straight probe), DAC curve (angle probe)
6. Choose the function setting
7. Detecting flaw in the workpiece
8. Record the flaws
9. Power off the instrument after operation
Instrument Standard Configuration
No. | Item | Qty | Remarks | |
Standard config. | 1 | Main unit | 1 | with multi-color TFT LCD Display |
2 | Straight Beam Probe | 1 | 4 MHz, Φ10 | |
3 | Angle Beam Probe | 1 | 4 MHz, 8 mm×9 mm, 60° | |
4 | Probe Cable | 1 | Q9-C5,or optional C9- C5 | |
5 | Battery Module | 1 | 8.8 amp hour (MB-03) | |
6 | Power Adapter | 1 | ||
7 | Supporting pillar | 1 | ||
8 | Attached files | 1 | ||
9 | Datapro Software | 1 | ||
10 | USB Cable | 1 | MUSB01 | |
11 | Power Cable | 1 | ||
12 | ABS Case | |||
Optional config. | 1 | Protective Cover for Main Unit | ||
2 | Various Probes | Selected according to the need like Dual-crystal Straight P,single crystal Straight Probe and so on |
Attention
1. During pressing key operation, please not be too hard. Please not use the hands with much oil or mud for operating the instrument keypad to avoid affecting the keypad working life.
2. Please clear the instrument cover after operation
3. Please keep the instrument in a dry and clean place
4. Please avoid oil, water or other liquids into the instrument and clean the instrument surface regularly.
5. Make sure not twist or press the probe cable, communication cable and power cable. Please grasp the plug root during inserting or pulling the cable. Don’t grasp the cable for pulling or inserting.
6. Please make sure the standard battery for working power adapter for charging. Otherwise, the instrument would be damaged easily.